Arată înregistrarea sumară a articolului

dc.contributor.authorȚanța, Ovidiu-Magdin
dc.contributor.authorRomanescu, Adrian-Neculai
dc.contributor.authorCenușă, Mihai
dc.contributor.authorNițan, Ilie
dc.contributor.authorPoienar, Mihaela
dc.date.accessioned2018-08-01T12:34:46Z
dc.date.available2018-08-01T12:34:46Z
dc.date.issued2015
dc.identifier.urihttp://10.11.10.50/xmlui/handle/123456789/5213
dc.descriptionDue to their reliability, robustness and multitude of variants of motors, electric machines are commonly used in industrial drives. Although they are relatively simple pieces of equipment, asynchronous motors can sometimes malfunction because of various reasons. Whether it is a problem in the supply network (lack of a phase, wrong phase sequence, different phase voltages, etc.) or an internal fault in the stator winding (interrupted winding, reversing the winding so that it begins with the end, shortened coils, etc.) motors diagnosis was a constant concern among specialists. Although a number of classic solutions are known, generally pertaining to the type of defect assumed, this paper proposes a completely new approach applicable to all types of anomalies that may occur in the functioning of these engines.ro_RO
dc.language.isoenro_RO
dc.publisherUniversitatea "Dunărea de Jos" din Galațiro_RO
dc.subjectferrofluidro_RO
dc.subjectrotating magneticro_RO
dc.subjectfieldro_RO
dc.subjectasynchronous motorro_RO
dc.titleSolutions for Diagnosing Faults in an Asynchronous Motor Stator Through a Ferrofluid Installationro_RO
dc.typeArticlero_RO


Fișiere la acest articol

Thumbnail

Acest articol apare în următoarele colecții(s)

Arată înregistrarea sumară a articolului